| Nominal conductor Diameter in mm. |
0.4 |
0.5 |
0.65 |
0.9 |
| Conductor Resistance in Ohm/km |
|
|
|
|
| Maximum Average CR of all pairs |
143 |
92 |
62 |
28 |
| Maximum CR of Individual Conductor |
150 |
96 |
64 |
30 |
| Minimum CR of Individual Conductor |
---- |
---- |
---- |
---- |
| ConductorResistance unbalance |
|
|
|
|
| Maximum Average RU of Individual pairs |
3.6 |
2.3 |
1.4 |
0.7 |
| Minimum RU of Individual pairs |
10.8 |
6.7 |
3.9 |
2 |
| Attenuation (in db/km) |
---- |
----- |
---- |
---- |
|
------ |
----- |
----- |
---- |
| Dielectric Strength (kv) |
|
a) Conductor to conductor |
1 KV AC for 3 Sec |
b) Conductor to sheath |
1 KV AC for 3 Sec |
| Mutual Capacitance (in nF/km) |
|
| Individual Max |
100 nF/Km |
| Average Max |
75 +/-4 nF/Km |
| Capacitance Unbalance Pair to Pair (in pF/km) |
22 +/-500 Mtr. |
| RMS value of Pair to Pair Individual |
150 P +/- 500 Mtr. |
| Maximum individual combination values |
|
| Maximun Average combination values |
|
| Insulation Resistance (Minimum) in Megaohm/km |
250 Mohm/Km |